HRVS-DN Medium Voltage soft starter

MEDIUM VOLTAGE SOFT STARTER

Digital Medium Voltage Soft Starters 

for Motors 30-3000A, 1500-15000V, 30KW - 60000KW

Medium Voltage Soft Starter Integrated Motor Insulation Protection

Introduction

Which medium voltage soft starter is considered as the most reliable soft starter in todays' Industrial and Marine markets ? The HRVS-DN is a third generation, digital, Medium Voltage Soft Starter, designed for use with standard MV asynchronous and synchronous motors. This highly sophisticated soft starter ensures smooth, step-less acceleration and deceleration, eliminating high inrush current and damaging mechanical torque on startup and mechanical wear on stopping. The HRVS-DN is available as a stand-alone product or as part of a complete system including Line and/or Bypass Contactors. Additional options for medium voltage soft starter include Load Break Switch, Motor Protection Relay, Digital Multi-meter, etc. 

We can customize our medium voltage soft starters to solve all of your inrush and startup problems. To see what we can do for you, become a distributor now and sign up .

 

Advantages at a Glance for the HRVS-DN Medium Voltage Soft Starter

  • Eliminates high inrush current and high mechanical torque on startup.
  • Soft, stepless acceleration & deceleration.
  • Unique starting & stopping characteristics.
  • User friendly, straight forward set-up and operation.
  • Sophisticated motor protection package.
  • Heavy duty design: 50°C ambient temperature.
  • Innovative low voltage test mode - full function-testing with a small L.V motor, using LV mains.
  • Advanced Electronic Potential Transformer utilizing Patent Pending "wireless" fiber-optic controlled firing system.
  • Each starter is tested for Partial Discharge (corona) to ensure long term reliability.
  • Power factor capacitors can be connected directly to the upstream contactor.
  • IP30-standard, higher protection by special order.
  • Two optional methods of delivery: Chassis type for self assembly or Complete system
  • RS485 Communication with MODBUS, MODBUS/TCP, PROFIBUS or Device-Net protocols (others available on request)
  • Wide 45-65Hz Auto-tracking frequency range realized by special software with unique hardware arrangement.
    (designed for Marine, Offshore and Generators operating under continuous frequency fluctuation)
  • Torque and current starting and stopping characteristics.
  • Pump control software.
  • Analog output option.
  • Motor Insulation Protection option (with programmable alarm and trip levels via seperate additional output).

 

Medium Voltage Soft Starters Range: 2300-7200V, 30-3000A 

 

medium voltage soft starter line by solcon

 

 

medium voltage soft starters in formation

 

Medium Voltage Soft Starters Range: 10000-13800V, 30-3000A 

medium voltage soft starter Range:10000-13800V, 60-2500A

 

Medium Voltage Soft Starters Range: 13800-15000V, 30-3000A

Medium Voltage Soft Starter Range: 13800-15000V, 60-2500A

 

Approvals of our products and Medium Voltage Soft Starters

Some of the approval bureau's we work with :  

     

as well as :  BV, RINA, Gost-R and others.

Starting & Stopping

  • Soft start and soft stop
  • Current limit
  • Torque & Current Control ramps
  • Pump Control characteristics
  • Pulse (kick) start
  • Tacho/encoder feedback (option)
  • Dual Adjust - 2 start/stop characteristics for varying loads, two speed motors, etc.
Soft starting and stopping utilizing our world renown "Pump Control Program"- choose the most effective curve for acceleration, deceleration and adjust for final torque. 

medium voltagesoft starter statistics


 

Set-up & Supervision of a Medium Voltage Soft Starter

  • Illuminated LCD with 2 lines, 16 characters each.                               
  • Selectable languages: English, German, French or Spanish.
  • The LCD displays motor current, fault description as well as statistical data.
  • Easy set-up using six soft-touch keys to change preprogrammed default parameters.
  • Eight LEDs for a quick status display: 
    • Control voltage On & Self Test OK                                          
    • Motor soft starting                                                          
    • Motor running
    • Motor soft stopping
    • Motor stopped
    • Test Mode Activated
    • Dual Adjust mode
    • Fault medium voltage soft starter digital display
 

Statistics

  • Last Starting Period
  • Last Start Maximum Current
  • Total Run Time
  • Number of Starts
  • Last Trip
  • Trip Current
  • Total Number of Trips
  • Historical Trip Event Recorder (10 Event conditions)

Control Inputs & Outputs for a Medium Voltage Soft Starter

  • Control voltage: 110-120, 220-240VAC / 50-60Hz or 110 - 220VDC to be specified at time of order.
  • Separate inputs for Start, Stop (Emergency) and Soft Stop.
  • Two programmable External fault inputs - will stop the motor 2 sec. after the contact closes
  • Aux. Contacts - three C/O relays, 8A, 250V, 2000VA (four C/O relays when Insulation option is used) :
    1) Immediate Relay - changes position upon start signal, with adjustable On & Off delays.
    Returns to original position upon Voltage Outage, Fault, Stop signal and Soft stop signal.
    at the end of soft stopping process. It can also be configured as a "Shear-pin Alarm" contact.
    2) End of Acceleration Relay - operates upon completion of starting process, with adjustable
    On delay. Returns to original position upon Voltage outage, Fault, Stop and Soft Stop signals.
    3) Fault Relay - can be programmed as:
         Fault - changes position upon Fault, returns to original position upon Reset.
         Fault-Fail-Safe - changes position upon control voltage connection, returns upon fault.
  • 4) Insulation Alarm relay - changes position upon insulation detection at a pre-programmed level.

 

 

Typical Applications for a Medium Voltage Soft Starter

  • Fans and centrifuges
  • Conveyors and monorail systems
  • Pumps, Compressors and Chillers
  • Starting large motors from weak power supply
    (diesel generators, long supply lines, etc.)

       

Marine & Offshore Applications for a Medium Voltage Soft Starter

  • Thrusters
  • Cargo Pumps (LNG, LPG, etc.)  
  • Water & Ballast pumps
  • Refrigeration compressors
  • Hydraulic pumps & power packs
  • Main Propulsion (Variable Pitch Propellers)

 

 

 

 

 

 

 

 

 

 

 

 

 

Northern Swan, soft starting 8 cargo pumps and 2 compressors.

Courtesy: Woodside

Nothern Swan uses medium voltage soft starters
   

 

 Comprehensive Motor & Starter Protection
with Occurrence status table
Active During
Start Run Stop Soft Stop
Too many starts & Start Inhibit Time      
Electronic Overload with selectable curves      
Shear Pin (Jam)
    Starter Protection - trip function at 850% FLC in less than 1 cycle
 
Motor Protection - trip function
    During Start-factory set at 850% FLA in less than 1 cycle
   
    During Run-adjustment 200-850% FLA with adjustable delay
     
Programmable setting
    Starter Protection - trip function at 850% FLC
 
Motor Protection - Alarm & Trip functions
On fault "Immediate Relay" acts as alarm w/adjustable delay.
Trip will not occur if fault is cleared within the time delay.
    During Start - preset at 850% FLA with adjustable delay
   
    During Run - prog. 200-850% FLA with adjustable delay
     
Under current      
Unbalance Current  
Ground Fault Current      
Phase loss  
Phase sequence  
Under voltage. Time delay is overridden in a "No-Volt" case  
Over voltage with adjustable time delay  
Under / Over Frequency when range exceeds "Auto Tracking"  
Long start time (Stall protection)      
Shorted SCR & Wrong connection (Load Loss)    
External fault 1 & 2
SCR protection by Metal Oxide Varistors (MOV)
Starter over-temperature
Starter internal test Passed
When supply voltage is connected and after the "On" LED is lit.
Power ON & NO Start signal      
By-Pass contactor Open      

 

Scope of supply

Chassis type or Cabinet (IP 30-67) or NEMA, with L.V. & M.V. segregated compartments or as Metal-Clad.
Single or Multi-Motor Versions.

     Single : One Soft-Starter and One Motor

     Multi : One Soft-Starter and Two to Four Motors

  • HRVS-DN M.V. soft starter
  • Line & Bypass Vacuum Contactors
  • Low voltage control system

Options for a Medium Voltage Soft Starter

         ·         Insulation Alarm - where motor insulation is continuously checked. Alarm and Trip levels are programmable

·         Communication: RS 485 with MODBUS, MODBUS-TCP, PROFIBUS or Device-Net

·         Analogue Output of motor current
(field programmable 0-10VDC, 0/4-20mA or inverse)

·         Motor Protection Relay MPS 3000 with up to 10 temperature inputs (Thermistors / RTDs)
consult factory for further details

·         Main Isolator including handle, Motor Protection type main fuses (with or without blown fuse indicator) etc (Incoming Cabinet containing all the options)

·         Digital Power, Voltage and Current Meter DPM-10, for continuous parameter display.

 

 

 

Cross Reference Numbers for Solcon Medium Voltage soft-starters HRVS-DN manufactured for international Brand labeling corporations:

6sf1106-0aa

6sf1111-0aa

6sf1114-0aa

6sf1120-0aa

6sf1125-0aa

6sf1130-0aa

6sf1132-0aa

6sf1140-0aa

6sf1150-0aa

6sf1160-0aa

 

6sf1106-0ba

6sf1111-0ba

6sf1114-0ba

6sf1120-0ba

6sf1125-0ba

6sf1130-0ba

6sf1132-0ba

6sf1140-0ba

6sf1150-0ba

6sf1160-0ba

 

6sf1106-0ca

6sf1111-0ca

6sf1114-0ca

6sf1120-0ca

6sf1125-0ca

6sf1130-0ca

6sf1132-0ca

6sf1140-0ca

6sf1150-0ca

6sf1160-0ca

 

6sf1106-0ca

6sf1111-0ca

6sf1114-0ca

6sf1120-0ca

6sf1125-0ca

6sf1130-0ca

6sf1132-0ca

6sf1140-0ca

6sf1150-0ca

6sf1160-0ca

 

6sf1106-0da

6sf1111-0da

6sf1114-0da

6sf1120-0da

6sf1125-0da

6sf1130-0da

6sf1132-0da

6sf1140-0da

6sf1150-0da

6sf1160-0da

 

6sf1106-0ea

6sf1111-0ea

6sf1114-0ea

6sf1120-0ea

6sf1125-0ea

6sf1130-0ea

6sf1132-0ea

6sf1140-0ea

6sf1150-0ea

6sf1160-0ea

 

 

6sf1106-0ab

6sf1111-0ab

6sf1114-0ab

6sf1120-0ab

6sf1125-0ab

6sf1130-0ab

6sf1132-0ab

6sf1140-0ab

6sf1150-0ab

6sf1160-0ab

 

6sf1106-0bb

6sf1111-0bb

6sf1114-0bb

6sf1120-0bb

6sf1125-0bb

6sf1130-0bb

6sf1132-0bb

6sf1140-0bb

6sf1150-0bb

6sf1160-0bb

 

6sf1106-0cb

6sf1111-0cb

6sf1114-0cb

6sf1120-0cb

6sf1125-0cb

6sf1130-0cb

6sf1132-0cb

6sf1140-0cb

6sf1150-0cb

6sf1160-0cb

 

6sf1106-0cb

6sf1111-0cb

6sf1114-0cb

6sf1120-0cb

6sf1125-0cb

6sf1130-0cb

6sf1132-0cb

6sf1140-0cb

6sf1150-0cb

6sf1160-0cb

 

6sf1106-0db

6sf1111-0db

6sf1114-0db

6sf1120-0db

6sf1125-0db

6sf1130-0db

6sf1132-0db

6sf1140-0db

6sf1150-0db

6sf1160-0db

 

6sf1106-0eb

6sf1111-0eb

6sf1114-0eb

6sf1120-0eb

6sf1125-0eb

6sf1130-0eb

6sf1132-0eb

6sf1140-0eb

6sf1150-0eb

6sf1160-0eb

  

6sf1106-0ac

6sf1111-0ac

6sf1114-0ac

6sf1120-0ac

6sf1125-0ac

6sf1130-0ac

6sf1132-0ac

6sf1140-0ac

6sf1150-0ac

6sf1160-0ac

 

6sf1106-0bc

6sf1111-0bc

6sf1114-0bc

6sf1120-0bc

6sf1125-0bc

6sf1130-0bc

6sf1132-0bc

6sf1140-0bc

6sf1150-0bc

6sf1160-0bc

 

6sf1106-0cc

6sf1111-0cc

6sf1114-0cc

6sf1120-0cc

6sf1125-0cc

6sf1130-0cc

6sf1132-0cc

6sf1140-0cc

6sf1150-0cc

6sf1160-0cc

 

6sf1106-0dc

6sf1111-0dc

6sf1114-0dc

6sf1120-0dc

6sf1125-0dc

6sf1130-0dc

6sf1132-0dc

6sf1140-0dc

6sf1150-0dc

6sf1160-0dc

  

6sf1106-0ec

6sf1111-0ec

6sf1114-0ec

6sf1120-0ec

6sf1125-0ec

6sf1130-0ec

6sf1132-0ec

6sf1140-0ec

6sf1150-0ec

6sf1160-0ec

 

  Medium Voltage Soft Starters Handbook. Medium Voltage versatility in one small package.